Installation and Operating Instructions
18 Installation
Network
NOTE: Do NOT connect the Intellex unit to a network unless you also install the
Network Client on the network. We recommend the use of shielded twisted-
pair cable for network operation.
Connect the cable from the local area network to Connector 7 (Network). Use
Category 5 twisted-pair Ethernet cable (CAT 5 TPE). Refer to the Network Client
Installation and Operating Instructions for more information.
RACK-MOUNTING THE RMS UNIT
The Intellex RMS has built-in slide rails for rack-mounting the unit.
CAUTION: You must mount the unit in a fully-supported rack. The rack must be
equipped with EIA-310-D standard 19-inch front and rear mounting
flanges.