About View Manager 16 Plus 1-7
Interfacing With the POS/EM Value System
Some View Manager 16 Plus systems interface with the Point-of-
Sale/Exception Monitoring (POS/EM) Value system. The POS/EM Value
system monitors the activity that takes place at the cash registers.
POS/EM Value documents those transactions that it considers exceptions to
the norm. When it documents one of these exceptions, it can print out the
actual register receipt and/or instruct a camera to view and record the
transaction as it happens.
When the system is in the camera control mode and an exception occurs at a
cash register, the POS/EM Value system can take control of a camera (if it
has been configured to do so). The POS/EM Value system will not affect the
View Manager 16 Plus system unless the T
OUCH TRACKER is in the camera
control mode.
You can determine whether or not you want the POS/EM Value system to
have priority over your system's cameras. You use the C button on the Main
T
OUCH TRACKER to indicate this. Each time you press the C button you
toggle back and forth between POS/EM priority over the cameras and View
Manager 16 Plus priority over the cameras.
If a “+” appears on the LCD, this indicates that POS/EM Value will take
control of a camera if an exception occurs at a register. If a “–” appears on
the LCD, this indicates that POS/EM Value will never take control of a
camera when an exception occurs.
The POS/EM Value system will only affect the Main monitor and the Main
T
OUCH TRACKER. Should POS/EM take control over a camera, you will still
be able to use the Call T
OUCH TRACKER as normal, and use it to select the
affected camera and manually take control of it.
An Overview of the TOUCH TRACKER
The TOUCH TRACKER, shown here, is a video control station that provides
you with easy access to a variety of video control features—from basic
camera control to advanced automated functions.